Operating Temperature: 0–100 °C (For cold and hot potable water)
Maximum Operating Pressure: 16 bar / 1600 kPa (For cold and hot potable water)
Molybdenum Content: Minimum 2.3%
Corrosion Resistance: High resistance to corrosion, especially in aggressive or high-humidity environments
Protection: Leakproof plug provided to protect threads from dust and dirt before installation
Description
The Geberit Mapress Stainless Steel Nipple is designed to provide a secure connection between two threaded components within press-fit systems. It is suitable for a range of applications, including drinking water installations, industrial piping systems, and areas where high corrosion resistance is required. Made from high-quality CrNiMo steel, this nipple offers excellent durability and reliability, making it ideal for use in demanding environments with high temperatures, pressures, or aggressive liquids.
Key Features
High Molybdenum Content: Manufactured from CrNiMo steel 1.4401, with a minimum molybdenum content of 2.3%, offering superior resistance to corrosion and ensuring longevity in aggressive environments.
Versatile Applications: This stainless steel nipple is suitable for a wide range of applications, including potable water systems, industrial piping, heating and cooling systems, and chemical installations. Its high corrosion resistance makes it especially suitable for environments with aggressive liquids or high hygiene requirements.
Hygienic and Safe: The Geberit Mapress Stainless Steel Nipple is suitable for use in systems that require thermal and chemical disinfection, ensuring that it meets stringent hygiene standards. Ideal for use in sensitive installations such as drinking water systems, hospitals, and food processing plants.
Sprinkler System Approved: This product is approved for use in ‘wet,’ ‘wet/dry,’ and ‘dry’ sprinkler systems. The nipple has received VdS, FM, and LPCB certifications, ensuring compliance with high safety standards.
Comprehensive System: As part of the Geberit Mapress Stainless Steel system, the nipple is compatible with a wide range of fittings and adaptors. With over 500 different components, the system provides maximum flexibility for installations, allowing for transitions and adaptors to other Geberit piping systems.
Corrosion Protection: Delivered with a leakproof plug already fitted, this ensures reliable protection against dust and dirt until installation, keeping the nipple free from contaminants during transportation and storage.
Easy Identification: Geberit Mapress fittings are identified by their distinctive blue indicator ring, making it easy to distinguish between different components and ensure the correct installation.
SKU
Article Number
DN
d
di
S
L
487586
32050
12
15 mm
13 mm
1 mm
5 cm
487587
32051
15
18 mm
16 mm
1 mm
5 cm
487588
32052
20
22 mm
19.6 mm
1.2 mm
5.2 cm
487589
32053
25
28 mm
25.6 mm
1.2 mm
5.6 cm
487590
32054
32
35 mm
32 mm
1.5 mm
6.2 cm
487591
32055
40
42 mm
39 mm
1.5 mm
8 cm
487592
32056
50
54 mm
51 mm
1.5 mm
9 cm
Application Purposes
Operating Temperature
Maximum Operating Pressure
For cold and hot potable water
0–100 °C
16 bar / 1600 kPa
For cooling and heating water without antifreeze agent
0–100 °C
16 bar / 1600 kPa (1)
For cooling and heating water with antifreeze agent
–30 °C to +120 °C
16 bar / 1600 kPa (1)
For district heating water ≤ 120 °C
0–120 °C
16 bar / 1600 kPa (1)
For saturated steam ≤ 120 °C
0–120 °C
2 bar/200 kPa (1)
For service water and process water
0–100 °C
16 bar / 1600 kPa (5)
For treated water
0–100 °C
16 bar / 1600 kPa (6)
For rainwater with a pH value of > 6.0
0–100 °C
16 bar / 1600 kPa
For grey and black water with pH value > 6.0
0–100 °C
16 bar / 1600 kPa
For extinguishing water (wet)
0–100 °C
16 bar / 1600 kPa
For sprinklers (wet)
0–100 °C
16 / 10 bar 1600 / 1000 kPa
For chemicals and technical liquids
Upon request
Upon request (5)
(1) Use of inhibitors, corrosion-protection agents, antifreeze agents only after approval by Geberit
(2) Lifetime with collector standstill: 200 h/a at 180 °C; 60 h/a at 200 °C; total 500 h/lifetime at 220 °C
(3) 10 bar / 1000 kPa for MasterFix and MeplaFix
(4) 16 bar / 1600 kPa for d22–76.1 mm, 10 bar / 1000 kPa for d88.9–108 mm
(5) Following Geberit approval
(6) Application range according to TI "Treated Waters"
Application Purposes
Operating Temperature
Maximum Operating Pressure
For Compressed Air (Oil Purity Class 0-3)
0-100°C
25/16/12 bar
2500/1600/1200 kPa (5)
(5) Oil purity class in accordance with ISO 8573-1:2010E; for details on moisture and particles, see technical information "Geberit Piping Systems for Compressed Air Installations"
IMPORTANT: The technical data given on this website is for preliminary information purposes only and is published without guarantee. All line drawings are for illustrative purposes only and should not be regarded as wholly accurate in every detail. We reserve the right to withdraw or to alter the specification of any product without notice. For more information, please consult our Terms of Business.
If you require any further information, our excellent customer service team is here to help so please call us on 01794 835835.