Useful Information
What is a Bush Used For?
Fernco (previously known as Flexseal) Bushes, are primarily used as additional components in conjunction with Shear Banded Couplings or Lateral Connection Saddles in drainage systems. Their main function is to increase the outside diameter of a pipe to ensure a snug and secure fit when the existing pipe is too small for the coupling or saddle being used. This is particularly useful in scenarios where pipes with significantly different diameters need to be connected.
Key Features
- Versatile Application: Ideal for use when there is a notable difference in the outside diameters of pipes being connected.
- Customizable: They can be manufactured to meet specific site and application requirements, offering tailored solutions.
- High-Performance Seal: Ensures a high-performance seal on low-pressure pipes, maintaining the integrity of the connection.
- Standard Compliance: Manufactured to meet WIS 4-41-01 standards and conform to BS EN 681-1 and BS EN 295-1:2013.
Specifications
- Size Range: Available in a range from 11mm to 265mm, accommodating various pipe sizes.
- Material: Made from high-quality EPDM for durability and reliability.
- Temperature Range: Suitable for temperatures from -50°C to 80°C continuously, and up to 100°C intermittently.
SKU | Fernco Code | Pipe OD Min/Max (mm) | Bush Thickness (mm) | Pipe OD Increase (mm) | Bush OD Min/Max (mm) |
484458 | B09-37 | 30 - 37 | 9 | 18 | 48 - 55 |
484459 | B06-43 | 35 - 40 | 6 | 12 | 47 - 52 |
484460 | B23-65 | 55 - 65 | 23 | 46 | 101 - 111 |
484461 | B17-76 | 65 - 76 | 17 | 34 | 99 - 110 |
484462 | B08-95 | 85 - 95 | 8 | 16 | 101 - 111 |
484463 | B12-95 | 85 - 95 | 12 | 24 | 109 - 119 |
484464 | B06-102 | 92 - 102 | 6 | 12 | 104 - 114 |
484465 | B08-105 | 95 - 105 | 8 | 16 | 111 - 121 |
484466 | B08-115 | 105 - 115 | 8 | 16 | 121 - 131 |
484467 | B15-115 | 105 - 115 | 15 | 30 | 135 - 145 |
484470 | B07-132 | 122 - 132 | 7 | 14 | 136 - 146 |
484468 | B12-125 | 115 - 125 | 12 | 24 | 139 - 149 |
484469 | B19-132 | 122 - 132 | 19 | 38 | 160 - 170 |
484471 | B08-160 | 150 - 160 | 8 | 16 | 166 - 176 |
484477 | B06-178 | 168 - 178 | 6 | 12 | 180 - 190 |
484473 | B12-166 | 156 - 166 | 12 | 24 | 180 - 190 |
484472 | B16-164 | 154 - 164 | 16 | 32 | 186 - 196 |
484475 | B26-168 | 158 - 168 | 26 | 52 | 210 - 220 |
484476 | B08-170 | 160 - 170 | 8 | 16 | 176 - 186 |
484478 | B08-180 | 170 - 180 | 8 | 16 | 186 - 196 |
484479 | B33-205 | 195 - 205 | 33 | 66 | 261 - 271 |
484481 | B08-265 | 255 - 265 | 8 | 16 | 271 - 281 |
484482 | B16-250 | 240 - 250 | 16 | 32 | 272 - 282 |
How and Where to Install
Fernco Bushes are straightforward to install:
- With Shear Banded Couplings: Check the maximum tolerance between the outside diameters of the pipes to be connected. If the difference exceeds this tolerance, use a bush to fill the gap on the smaller pipe.
- With Lateral Connection Saddles: When connecting pipes (other than clay) into saddles designed for thicker-walled materials, use a bush to increase the outside diameter of the pipe to fit within the saddle’s tightening range.
- Fit the Bush: Place the bush over the smaller diameter pipe to fill the void between the pipe and the inside of the coupling or saddle.
Compliance Note: For adopted drainage pipelines, as specified under WIS 4-41-01, a Shear Banded Coupling and Bush should be used to ensure alignment and protection against vertical shear loads.